NON-35 CLASS K5 FUSE BUSSMANN
NON-35 CLASS K5 FUSE BUSSMANN – Industrial 35A 250VAC/125VDC General-Purpose One-Time Fuse
The NON-35 CLASS K5 FUSE BUSSMANN (Model NON-35) is an industrial-grade, general-purpose non-time-delay power fuse manufactured by Eaton’s Bussmann series. Engineered specifically to deliver foundational overcurrent and short-circuit protection for lighting systems, heating circuits, non-inductive loads, and general electrical branch circuits, this 35-amp, 250 VAC / 125 VDC fuse provides economical circuit protection across commercial and industrial distribution panels.
Featuring a fast-acting one-time response profile, the NON-35 CLASS K5 FUSE BUSSMANN clears quickly during short circuits and continuous thermal overloads to safeguard connected equipment, conductors, and switches. It offers an interrupting rating of 50 kA RMS Symmetrical at 250 VAC and 50 kA at 125 VDC. Built in a standard UL Class K5 ferrule body format (13/16”x 3”), this fuse fits seamlessly into standard 250V Class H and Class K fuse blocks, safety switches, and disconnect panels.
Key Features of the NON-35 CLASS K5 FUSE BUSSMANN
-
Basic General-Purpose Protection: Optimized for non-inductive electrical circuits where motor-starting inrush surges are absent, delivering reliable and economical protection.
-
Dual Voltage Operation: Fully rated for continuous operation at 250 VAC and 125 VDC, providing multi-system capability across AC power and auxiliary DC circuits.
-
50kA Interrupting Rating: Safely interrupts high prospective fault currents up to 50 kA RMS Symmetrical at 250 VAC and 50 kA at 125 VDC.
-
Standard Industrial Ferrule Body: Standardized 13/16 inch x 3 inch (20.6 x 76.2 mm) body dimensions ensure broad compatibility across standard 250V fuse clips.
-
Cost-Effective One-Time Design: Serves as a budget-friendly overcurrent solution for lighting panels, service disconnects, and resistance heating elements.
-
Durable Physical Construction: Constructed with a high-strength composite body fitted with heavy-duty end caps for maximum conductivity and mechanical strength.
Common Applications and Practical Usage
The straightforward fast-acting clearing speed, 35A rating, and physical ferrule profile of the NON-35 CLASS K5 FUSE BUSSMANN make it widely used across general industrial and commercial installations:
-
Commercial & Industrial Lighting Panels: Safeguards main feeder and branch circuits feeding high-density fluorescent, LED, and incandescent lighting grids.
-
Resistance Heating Systems: Protects duct heaters, baseboard electric heaters, and industrial process heating elements from thermal overloads.
-
General Power Distribution: Provides primary or secondary branch protection in standard 250V panelboards, switchboards, and fused safety switches.
-
Non-Inductive Electrical Loads: Ideal for purely resistive or light commercial loads where startup surge currents are negligible.
Technical Specifications
The core electrical, physical, and compliance parameters for the NON-35 CLASS K5 FUSE BUSSMANN are detailed below:
| Parameter Specification | Technical Details & Operational Values |
| Component Classification | Industrial Class K5 General-Purpose One-Time Fuse |
| Primary Target Keyword | NON-35 CLASS K5 FUSE BUSSMANN |
| Brand / Series | Eaton Bussmann Series / NON General Purpose |
| Catalog Model / Part No. | NON-35 |
| Amperage Rating | 35 Amps (35 A) |
| Voltage Rating | 250 VAC / 125 VDC |
| Interrupt Rating (IR) | 50 kA RMS Symmetrical at 250 VAC / 50 kA at 125 VDC |
| Response Characteristic | Fast-Acting / Non-Time-Delay |
| Fuse Class & Form Factor | UL Class K5 / Class H Ferrule (13/16” x 3” / 20.6 mm x 76.2 mm) |
| Terminal Connection Type | Ferrule End Caps |
| Body Material | High-Strength Composite Tube with Metallic Caps |
| Agency Certifications | UL Listed (Std 248-9, Class K5), CSA Certified, CE, RoHS Compliant |
Operating Guidelines and Usage Tips
SAFETY NOTICE: Always isolate main power supplies and verify circuits are completely de-energized with a calibrated voltage tester before inspecting or replacing power fuses.
Holder Compatibility: Mount in standard 250V ferrule fuse blocks or safety disconnect switches (such as Bussmann H250 series holders).
Application Caution: For motor branch circuits or inductive transformer loads subject to heavy starting inrush, consider using dual-element time-delay fuses (such as Bussmann Fusetron FRN-R series) to avoid nuisance opening.
To review official low-voltage fuse standards and Class K5 protection requirements, consult the National Electrical Manufacturers Association (NEMA) Directory.
To check regional warehouse inventory availability or request commercial quotes for volume electrical fuses, visit the Control Qatar Contact Page.