LP-CC-30 TIME DELAY FUSE BUSSMANN

BUSSMANN TIME DELAY FUSE LP-CC-30

Category: Brand:

LP-CC-30 TIME DELAY FUSE BUSSMANN

LP-CC-30 TIME DELAY FUSE BUSSMANN – Industrial 30A 600VAC/300VDC Class CC Dual-Element Time-Delay Fuse

The LP-CC-30 TIME DELAY FUSE BUSSMANN (Model LP-CC-30) is a high-performance, ultimate-protection dual-element time-delay branch circuit fuse manufactured by Eaton’s Bussmann series. Engineered specifically to provide advanced overcurrent, short-circuit, and high-inrush protection for industrial motor circuits, control transformers, and power distribution systems, this 30-amp, 600 VAC 300 VDC Low-Peak™ Class CC fuse delivers maximum current limitation across compact automation panels.

Featuring dual-element time-delay performance, the LP-CC-30 TIME DELAY FUSE BUSSMANN holds a minimum 12-second time delay at 200% of its rated current. This allows temporary motor starting currents, transformer magnetizing inrushes, and inductive coil transients to pass without causing unwanted fuse openings. Under severe short-circuit conditions, its fast current-limiting action safely interrupts prospective fault currents up to 200 kA RMS Symmetrical at 600 VAC and 20 kA at 300 VDC. Constructed in a compact 13/32” x 1-1/2” (10.3 x 38.1 mm) melamine body format, it incorporates a physical Class CC rejection tip to prevent non-current-limiting fuses from being inserted into protected holders.

Key Features of the LP-CC-30 TIME DELAY FUSE BUSSMANN

  • Dual-Element Time-Delay Design: Holds a minimum 12-second time-delay at 200% rated load, eliminating nuisance tripping caused by motor startup surges and inductive transients.

  • Class CC Rejection Feature: Built with a standardized rejection tip that pairs exclusively with UL Class CC fuse blocks, preventing accidental insertion of lower-rated or non-current-limiting fuses.

  • High 200 kA Interrupting Capacity: Rated to safely interrupt short-circuit currents up to 200 kA RMS Symmetrical at 600 VAC (20 kA at 300 VDC), ensuring compliance with NEC® Section 110.9 safety standards.

  • Extreme Current Limitation: Limits peak let-through thermal energy (I^2t) and magnetic forces during short circuits, protecting downstream equipment and conductors from damage.

  • Dual AC/DC Voltage Rating: Operates continuously up to 600 VAC and 300 VDC, serving AC power systems and DC bus power circuits.

  • Type 2 “No Damage” Protection: Proper sizing can provide Type 2 coordinated short-circuit protection for NEMA and IEC motor controllers and contactors.

Common Applications and Practical Usage

The high breaking capacity, 30 A rating, and superior surge handling of the LP-CC-30 TIME DELAY FUSE BUSSMANN make it a protective device across industrial and commercial facilities:

  • Small Horsepower Motor Circuits: Provides compact branch-circuit protection and Type 2 “No Damage” protection for fractional and small AC motor branch circuits.

  • Control Transformer Primary Protection: Protects primary windings of industrial control transformers against short circuits while riding through heavy magnetizing inrush surges.

  • Solenoids, Contactors & Relays: Safeguards inductive control loads, electromagnetic valves, and contactor coils from sustained thermal overloads.

  • Industrial Control Panels & Branch Feeds: Ideal component for protecting low-amperage branch circuits, specialized equipment, and PLC output cards in 600 V machinery panels.

Technical Specifications

The core electrical, physical, and compliance specifications for the LP-CC-30 TIME DELAY FUSE BUSSMANN are detailed below:

Parameter Specification Technical Details & Operational Values
Component Classification Class CC Dual-Element Time-Delay Current-Limiting Fuse
Primary Target Keyword LP-CC-30 TIME DELAY FUSE BUSSMANN
Brand / Series Eaton Bussmann Series / Low-Peak™ LP-CC
Catalog Model / Part No. LP-CC-30
Amperage Rating 30 Amps (30A)
Voltage Rating 600 VAC / 300 VDC
Interrupt Rating (IR) 200 kA RMS Symmetrical at 600 VAC / 20 kA at 300 VDC
Response Characteristic Time-Delay (Min. 12 seconds at 200% current)
Fuse Class & Form Factor UL Class CC Rejection Ferrule (13/32” x 1-1/2” / 10.3 mm x 38.1 mm)
Terminal Connection Type Ferrule End Caps with Rejection Tip
Body Material Melamine Tube Casing with Nickel-Plated End Caps
Agency Certifications UL Listed (Std 248-4, Class CC, Guide JDDZ), CSA Certified, CE, RoHS Compliant

Operating Guidelines and Usage Tips

SAFETY NOTICE: Always isolate main power supplies and verify circuits are completely de-energized using a calibrated voltage tester prior to inspecting or replacing power fuses.

  • Holder Compatibility: Install exclusively in dedicated UL Class CC rejection fuse blocks or finger-safe DIN-rail modular holders (such as Bussmann CHCC series holders).

  • Motor Protection Sizing: For motor branch circuits, follow NEC® Article 430 rules, sizing the fuse between 150% and 175% of motor full-load current (FLA) to ensure complete protection without nuisance trips during motor startup.

To review official Class CC branch-circuit fuse standards and low-voltage current-limiting guidelines, consult the National Electrical Manufacturers Association (NEMA) Directory.

To check regional warehouse inventory availability or request commercial quotes for volume electrical fuses, visit the Control Qatar Contact Page.