8.5X31.5 CERAMIC FUSE 8A
8.5X31.5 CERAMIC FUSE 8A – High-Breaking Capacity gG/gL Cylindrical Cartridge Fuse
The 8.5X31.5 CERAMIC FUSE 8A is an industrial-grade 8 A low-voltage cylindrical cartridge fuse designed for full-range overcurrent and short-circuit protection in electrical distribution circuits, control panels, and industrial machinery. Built to the standardized 8.5 mm x 31.5 mm physical form factor (CH8 / 8 x 31 mm class), this ceramic fuse operates at a rated voltage of 400 V AC with a high interrupting capacity of up to 100 kA.
Utilizing a gG/gL operational characteristic curve (IEC 60269 / VDE 0636 standard), the 8.5X31.5 CERAMIC FUSE 8A provides comprehensive protection against both low-level thermal overloads and extreme short-circuit currents. The high-density steatite ceramic body, filled with fine silica quartz sand and capped with silver-plated copper ferrule terminals, ensures fast arc extinction and long-term thermal stability.
As illustrated in the product image, the fuse features a cylindrical white ceramic tube laser-printed with standard operational markings, including “8.5 x 31.5”, “400V~ 100kA”, “gG/gL”, “IEC 269”, “VDE0636”, and the “CE” mark, fitted with solid metallic end contact caps.
Key Features of the 8.5X31.5 CERAMIC FUSE 8A
-
High Breaking Capacity (100 kA at 400 V AC): Safely interrupts high-energy short-circuit fault currents up to 100 kA, preventing catastrophic equipment damage or arc flash risks.
-
Full-Range gG/gL Protection: Engineered to handle both slow thermal overload currents and instantaneous high-magnitude short circuits across general distribution circuits.
-
Steatite Ceramic Body Construction: High thermal resistance and mechanical strength body withstands extreme internal pressures during fault interruption without fracturing.
-
Silver-Plated Copper Contacts: Corrosion-resistant ferrule caps maintain low contact resistance, reducing power dissipation (2 R losses) across the fuse disconnect holder.
-
Quartz Sand Arc Extinguishing Medium: Packed with high-purity silica sand inside the ceramic core to rapidly absorb energy and suppress electrical arcs during element melting.
-
International Regulatory Compliance: Fully certified to IEC 60269-1 / IEC 60269-2, VDE 0636, and CE standards for global industrial compatibility.
Common Applications and Practical Usage
The high breaking capacity and compact footprint of the 8.5X31.5 CERAMIC FUSE 8A make it a standard protective component across industrial and commercial power distribution setups:
-
Modular Fuse Disconnect Holders: Mounts into standard rail-mounted 8.5 x 31.5 mm isolatable fuse carriers (such as Schneider Acti9 STI or Legrand carriers).
-
Industrial Control Panels & Automation: Protects auxiliary control transformers, relay power feeds, solenoid valves, and PLC power modules.
-
Lighting & Power Distribution Circuits: Serves as branch-circuit protection for commercial lighting panels, heating circuits, and small power supply lines.
-
Variable Frequency Drives (VFDs) & Power Supplies: Acts as primary input line protection for low-power motor drives and electronic power converter units.
Technical Specifications
The core electrical, mechanical, and regulatory parameters for the 8.5X31.5 CERAMIC FUSE 8A are summarized below:
| Parameter Specification | Technical Details & Operational Values |
| Component Classification | Cylindrical Ceramic Cartridge Fuse Link |
| Primary Target Keyword | 8.5X31.5 CERAMIC FUSE 8A |
| Physical Dimensions (varnothing x L) | 8.5 mm x 31.5 mm (Standard CH8 / 8 x 31 mm) |
| Rated Current (I_n) | 8 A |
| Rated Voltage (U_n) | 400 V AC |
| Interrupting Capacity (I_1) | 100 kA at 400 V AC |
| Utilization Category / Speed | gG / gL (Full-Range General Line Protection) |
| Body Material | High-Grade Steatite Ceramic |
| Contact Cap Material | Silver-Plated Copper Ferrules |
| Internal Filling | Quartz / Silica Sand Arc Suppressor |
| Applicable Standards | IEC 60269-1 / -2, IEC 269, VDE 0636, CE |
Installation Guidelines and Maintenance Tips
SAFETY NOTICE: Always isolate power supplies at the main circuit breaker before inserting or replacing cartridge fuses inside fuse carriers.
Holder Verification: Ensure the target fuse holder is rated for 8.5 x 31.5 mm cartridges and compatible with 400 V AC operational ratings.
Correct Replacement: Replace blown fuses only with the exact same current rating (8 A) and characteristic curve (gG/gL) to maintain downstream protection integrity.
To review official international standards for low-voltage fuse links and testing requirements, consult the official IEC 60269 Low-Voltage Fuses Standard Directory.
To check regional warehouse inventory availability or request commercial quotes for bulk procurement needs, please connect with our sales branch via the Control Qatar Contact Page.