8.5X31.5 CERAMIC FUSE 8A

CERAMIC FUSE 8.5X31.5 500V 8A

8.5X31.5 CERAMIC FUSE 8A

8.5X31.5 CERAMIC FUSE 8A – High-Breaking Capacity gG/gL Cylindrical Cartridge Fuse

The 8.5X31.5 CERAMIC FUSE 8A is an industrial-grade 8 A low-voltage cylindrical cartridge fuse designed for full-range overcurrent and short-circuit protection in electrical distribution circuits, control panels, and industrial machinery. Built to the standardized 8.5 mm x 31.5 mm physical form factor (CH8 / 8 x 31 mm class), this ceramic fuse operates at a rated voltage of 400 V AC with a high interrupting capacity of up to 100 kA.

Utilizing a gG/gL operational characteristic curve (IEC 60269 / VDE 0636 standard), the 8.5X31.5 CERAMIC FUSE 8A provides comprehensive protection against both low-level thermal overloads and extreme short-circuit currents. The high-density steatite ceramic body, filled with fine silica quartz sand and capped with silver-plated copper ferrule terminals, ensures fast arc extinction and long-term thermal stability.

As illustrated in the product image, the fuse features a cylindrical white ceramic tube laser-printed with standard operational markings, including “8.5 x 31.5”, “400V~ 100kA”, “gG/gL”, “IEC 269”, “VDE0636”, and the “CE” mark, fitted with solid metallic end contact caps.

Key Features of the 8.5X31.5 CERAMIC FUSE 8A

  • High Breaking Capacity (100 kA at 400 V AC): Safely interrupts high-energy short-circuit fault currents up to 100 kA, preventing catastrophic equipment damage or arc flash risks.

  • Full-Range gG/gL Protection: Engineered to handle both slow thermal overload currents and instantaneous high-magnitude short circuits across general distribution circuits.

  • Steatite Ceramic Body Construction: High thermal resistance and mechanical strength body withstands extreme internal pressures during fault interruption without fracturing.

  • Silver-Plated Copper Contacts: Corrosion-resistant ferrule caps maintain low contact resistance, reducing power dissipation (2 R losses) across the fuse disconnect holder.

  • Quartz Sand Arc Extinguishing Medium: Packed with high-purity silica sand inside the ceramic core to rapidly absorb energy and suppress electrical arcs during element melting.

  • International Regulatory Compliance: Fully certified to IEC 60269-1 / IEC 60269-2, VDE 0636, and CE standards for global industrial compatibility.

Common Applications and Practical Usage

The high breaking capacity and compact footprint of the 8.5X31.5 CERAMIC FUSE 8A make it a standard protective component across industrial and commercial power distribution setups:

  • Modular Fuse Disconnect Holders: Mounts into standard rail-mounted 8.5 x 31.5 mm isolatable fuse carriers (such as Schneider Acti9 STI or Legrand carriers).

  • Industrial Control Panels & Automation: Protects auxiliary control transformers, relay power feeds, solenoid valves, and PLC power modules.

  • Lighting & Power Distribution Circuits: Serves as branch-circuit protection for commercial lighting panels, heating circuits, and small power supply lines.

  • Variable Frequency Drives (VFDs) & Power Supplies: Acts as primary input line protection for low-power motor drives and electronic power converter units.

Technical Specifications

The core electrical, mechanical, and regulatory parameters for the 8.5X31.5 CERAMIC FUSE 8A are summarized below:

Parameter Specification Technical Details & Operational Values
Component Classification Cylindrical Ceramic Cartridge Fuse Link
Primary Target Keyword 8.5X31.5 CERAMIC FUSE 8A
Physical Dimensions (varnothing x L) 8.5 mm x 31.5 mm (Standard CH8 / 8 x 31 mm)
Rated Current (I_n) 8 A
Rated Voltage (U_n) 400 V AC
Interrupting Capacity (I_1) 100 kA at 400 V AC
Utilization Category / Speed gG / gL (Full-Range General Line Protection)
Body Material High-Grade Steatite Ceramic
Contact Cap Material Silver-Plated Copper Ferrules
Internal Filling Quartz / Silica Sand Arc Suppressor
Applicable Standards IEC 60269-1 / -2, IEC 269, VDE 0636, CE

Installation Guidelines and Maintenance Tips

SAFETY NOTICE: Always isolate power supplies at the main circuit breaker before inserting or replacing cartridge fuses inside fuse carriers.

  • Holder Verification: Ensure the target fuse holder is rated for 8.5 x 31.5 mm cartridges and compatible with 400 V AC operational ratings.

  • Correct Replacement: Replace blown fuses only with the exact same current rating (8 A) and characteristic curve (gG/gL) to maintain downstream protection integrity.

To review official international standards for low-voltage fuse links and testing requirements, consult the official IEC 60269 Low-Voltage Fuses Standard Directory.

To check regional warehouse inventory availability or request commercial quotes for bulk procurement needs, please connect with our sales branch via the Control Qatar Contact Page.

Scroll to Top