DMM-44/100 BUSSMANN MULTIMETER FUSE
DMM-44/100 BUSSMANN MULTIMETER FUSE – High-Interrupting 0.44 A 1000 VAC/VDC Fast-Acting Instrument Fuse
The DMM-44/100 BUSSMANN MULTIMETER FUSE (Model DMM-B-44/100 / DMM-44/100) is a specialized, high-interrupting fast-acting instrument fuse engineered specifically for digital multimeters (DMMs) and electrical test equipment. Manufactured by Eaton’s Bussmann series, this 0.44 -amp (440 mA), 1000 V fuse provides critical overcurrent and short-circuit protection for milliamp and microamp measurement inputs across professional diagnostic tools.
Designed to protect both the technician and sensitive meter circuitry, the DMM-44/100 BUSSMANN MULTIMETER FUSE features an exceptionally high interrupting rating of 10 kA at 1000 VAC/VDC}. In the event of accidental connection to high-energy industrial busbars or power lines while in current measurement mode, this ultra-fast fuse safely quenches severe arc faults inside the instrument. Built in a 10 x 35 mm (13/32” x 1-3/8”) cylindrical body filled with high-purity silica sand, it prevents meter explosions and flashovers.
As shown in the image, the fuse features a durable ceramic barrel with distinct blue-and-white labeling reading “BUSS® FUSE 1000V AC/DC 0.44 AMPERE DMM-44/100”, fitted on both ends with nickel-plated brass ferrule caps.
Key Features of the DMM-44/100 BUSSMANN MULTIMETER FUSE
-
High-Interrupting Voltage Rating: Rated for 1000 VAC and 1000 VDC with a 10 kA interrupting capacity, meeting CAT III 1000 V and CAT IV 600 V instrument safety standards.
-
Fast-Acting Response Speed: Clears overcurrent faults rapidly to prevent delicate internal meter circuitry and shunts from burning out.
-
Sand-Filled Arc Quenching: Constructed with internal silica sand fill that immediately cools and suppresses electrical arcs during high-voltage short-circuit events.
-
Precise 440 mA Current Protection: Specifically calibrated for the low-current mA mu A measurement ranges of leading digital multimeters.
-
Standardized 10 x 35 mm Size: Industry-standard 10 x 35 mm (0.406” 1.375”) physical dimensions ensure direct replacement compatibility with Fluke® and other major multimeter brands.
-
Nickel-Plated End Caps: Solid brass end caps with nickel plating ensure low resistance and long-term corrosion resistance.
Common Applications and Practical Usage
The strict safety requirements and precision calibration of the DMM-44/100 BUSSMANN MULTIMETER FUSE make it the standard replacement fuse across test and measurement equipment:
-
Digital Multimeter mA mu A Inputs: Serves as the primary protective replacement fuse for 440mA input jacks on industrial digital multimeters (including Fluke® 87V, 179, 289, and 1587 series).
-
Process Calibrators & Signal Injection Tools: Protects precision current loop calibrators, milliamp signal sources, and field service meters.
-
Electrical Test & Measurement Instruments: Provides high-voltage insulation and fault clearing for portable insulation testers, benchtop multimeters, and electrical analyzers.
Technical Specifications
The core electrical, physical, and compliance parameters for the DMM-44/100 BUSSMANN MULTIMETER FUSE are detailed below:
| Parameter Specification | Technical Details & Operational Values |
| Component Classification | High-Interrupting Fast-Acting Instrument / Multimeter Fuse |
| Primary Target Keyword | DMM-44/100 BUSSMANN MULTIMETER FUSE |
| Brand / Series | Eaton Bussmann Series / DMM-B |
| Catalog Model / Part No. | DMM-B-44/100 / DMM-44/100 |
| Amperage Rating | 0.44 Amps (440 mA) |
| Voltage Rating | 1000 VAC / 1000 VDC |
| Interrupt Rating (IR) | 10 kA RMS Symmetrical at 1000 VAC/VDC |
| Response Characteristic | Fast-Acting / Quick-Acting |
| Form Factor & Dimensions | Cylindrical Ferrule (10 x 35 mm / 13/32” x 1-3/8”) |
| Body Construction | Melamine / Ceramic Tube with Silica Sand Filling |
| Agency Certifications | UL Recognized (File E19180), CE, RoHS Compliant |
Operating Guidelines and Usage Tips
SAFETY NOTICE: Never replace multimeter fuses with general-purpose glass or low-voltage fuses. Using non-specified fuses in high-voltage test meters can lead to arc flash hazards and personal injury.
OEM Specification Matching: Always verify that the replacement fuse matches the exact amperage (0.44 A) and voltage (1000 V) specified in your meter’s user manual.
Routine Check: Periodically inspect multimeter fuses using the meter’s internal continuity check mode before performing high-voltage electrical diagnostics.
To review official test equipment safety standards and digital multimeter protection criteria, consult the International Electrotechnical Commission (IEC) Safety Portal.
To check regional warehouse inventory availability or request commercial quotes for volume electrical fuses, visit the Control Qatar Contact Page.