FNQ-R-20 TIME DELAY FUSE BUSSMANN

FNQ-R-20 TIME DELAY FUSE BUSSMANN

FNQ-R-20 TIME DELAY FUSE BUSSMANN – Industrial 20A 600VAC Class CC Current-Limiting Fuse

The FNQ-R-20 TIME DELAY FUSE BUSSMANN (Model FNQ-R-20) is an industrial-grade, dual-element time-delay Class CC rejection-type fuse manufactured by Eaton’s Bussmann series. Engineered specifically for high-inrush inductive loads, this 20-amp current-limiting fuse provides superior electrical protection for control transformers, solenoids, small motor branch circuits, and industrial control systems.

Unlike fast-acting fuses that blow under temporary current surges, the FNQ-R-20 TIME DELAY FUSE BUSSMANN features a minimum 12-second time-delay at 200% of its rated current. This allows harmless startup inrush currents to pass safely while maintaining rapid current-limiting clearing speeds during destructive short-circuit fault conditions up to 200kA RMS Symmetrical at 600VAC. Its rejection-style body ensures that lower-rated supplementary fuses cannot be mistakenly installed into Class CC fuse blocks, maintaining strict National Electrical Code (NEC®) safety compliance.

As shown in the image, the fuse features a high-durability white melamine body labeled with “Bussmann LIMITRON™ CURRENT LIMITING TIME-DELAY CLASS CC FUSE FNQ-R-20 600Vac 300Vdc”, capped with nickel-plated bronze ferrule end caps featuring the characteristic Class CC rejection pin tip.

Key Features of the FNQ-R-20 TIME DELAY FUSE BUSSMANN

  • Dual-Element Time-Delay Performance: Offers a minimum of 12 seconds time-delay at 200% rated load, eliminating nuisance fuse openings caused by motor startup surges and transformer inrush currents.

  • Class CC Rejection Feature: Built with a grooved rejection end-cap pin that prevents the insertion of non-rejection or lower-interrupting-rated supplementary fuses into Class CC fuse blocks.

  • High 200kA Interrupting Rating: Rated for 200kA RMS Symmetrical at 600VAC, ensuring high-level branch circuit protection under extreme fault conditions.

  • Advanced Current Limitation: Limits short-circuit peak let-through currents significantly, reducing mechanical thermal stress on downstream panel components.

  • Dual Voltage Compatibility: Rated for up to 600VAC and 300VDC systems for versatile deployment across AC and DC control circuits.

  • Durable Melamine Construction: Constructed with a high-strength melamine tube and nickel-plated end caps for high thermal stability and corrosion protection.

Common Applications and Practical Usage

The specialized inductive-load capability of the FNQ-R-20 TIME DELAY FUSE BUSSMANN makes it essential for heavy-duty industrial automation and control panels:

  • Control Transformer Protection: Ideal for protecting the primary side of industrial control transformers where startup magnetization inrush currents would blow fast-acting fuses.

  • Small Motor Branch Circuits: Delivers primary overcurrent and short-circuit protection for small fractional horsepower motors.

  • Solenoid & Contactor Circuits: Guards magnetic coils, actuators, and industrial relays from sustained overloads while allowing high peak pulling currents.

  • HVAC & Industrial Automation Panels: Used in commercial HVAC control boxes, variable frequency drive (VFD) input protection, and PLC power supplies.

Technical Specifications

The primary electrical, physical, and compliance parameters for the FNQ-R-20 TIME DELAY FUSE BUSSMANN are detailed below:

Parameter Specification Technical Details & Operational Values
Component Classification Class CC Time-Delay Current-Limiting Fuse
Primary Target Keyword FNQ-R-20 TIME DELAY FUSE BUSSMANN
Brand / Series Eaton Bussmann Series / LIMITRON™ FNQ-R
Amperage Rating 20 Amps (20A)
Voltage Ratings 600 VAC / 300 VDC
Interrupt Rating (IR) 200 kA at 600VAC / 20 kA at 300VDC
Response Characteristic Time-Delay (Min. 12 seconds at 200% current)
Fuse Class & Form Factor UL Class CC Rejection Type (13/32” x 1-1/2” / 10.3mm x 38.1mm)
Body Material & Terminals High-Grade Melamine Tube with Nickel-Plated Bronze Ferrules
Agency Certifications UL Listed (Std 248-4, Guide JDDZ), CSA Certified, CE, RoHS

Operating Guidelines and Usage Tips

SAFETY NOTICE: Always isolate power and de-energize circuits before servicing or replacing power fuses. Use proper lockout/tagout (LOTO) protocols and insulated fuse pullers.

  • Sizing for Transformers: Size the fuse at approximately 125% to 250% of the transformer primary full-load current (FLA) according to NEC Article 450 guidelines.

  • Fuse Block Matching: Pair with UL Class CC modular fuse blocks or DIN-rail holders (such as the Bussmann CHCC series) to utilize the physical rejection feature properly.

To review official Class CC time-delay fuse specifications and electrical installation codes, consult the National Electrical Manufacturers Association (NEMA) Directory.

To check regional warehouse inventory availability or request commercial quotes for volume electrical fuses, visit the Control Qatar Contact Page.