FNQ-R-4/10 TIME DELAY FUSE BUSSMANN
FNQ-R-4/10 TIME DELAY FUSE BUSSMANN – Industrial 0.4A 600VAC Class CC Current-Limiting Fuse
The FNQ-R-4/10 TIME DELAY FUSE BUSSMANN (Model FNQ-R-4/10) is a high-precision, 0.4-amp (4/10A) dual-element time-delay Class CC rejection-type fuse manufactured by Eaton’s Bussmann series. Engineered specifically for protecting sensitive low-amperage inductive circuits, this 600VAC LIMITRON™ current-limiting fuse provides superior electrical protection for small industrial control transformers, solenoids, relays, and automation equipment.
Designed to handle high temporary inrush currents without nuisance tripping, the FNQ-R-4/10 TIME DELAY FUSE BUSSMANN delivers a minimum 12-second time-delay at 200% of its rated current. This dual-element design allows harmless startup magnetization and inductive surge currents to pass safely, while maintaining rapid current-limiting response times during destructive short-circuit fault conditions up to 200kA RMS Symmetrical at 600VAC. Its rejection-style body prevents lower-rated or non-Class CC fuses from being mistakenly installed into rejection fuse blocks, maintaining strict National Electrical Code (NEC®) safety compliance.
As shown in the image, the fuse features a high-durability white melamine body clearly labeled with “Bussmann LIMITRONâ„¢ CURRENT LIMITING TIME-DELAY CLASS CC FUSE FNQ-R-4/10 600Vac”, capped with nickel-plated bronze ferrule end caps featuring the physical Class CC rejection pin tip.
Key Features of the FNQ-R-4/10 TIME DELAY FUSE BUSSMANN
-
Dual-Element Time-Delay Characteristic: Provides a minimum 12-second time-delay at 200% of rated load, absorbing momentary inrush current spikes without blowing unexpectedly.
-
Low-Amperage Precision Protection: Rated at 0.4 Amps (4/10A), offering accurate overcurrent protection for low-power control components and delicate instruments.
-
Class CC Rejection Feature: Built with a grooved rejection end-cap pin that physically prevents the insertion of non-rejection or lower-interrupting-rated supplementary fuses into Class CC fuse holders.
-
High 200kAÂ Interrupting Rating: Rated for 200kA RMSÂ Symmetrical at 600VAC, ensuring high-level branch and component circuit protection under maximum short-circuit conditions.
-
Extreme Current Limitation: Restricts thermal and magnetic energy let-through under fault conditions, shielding downstream panel components from physical damage.
-
Durable Melamine Construction: Built with a high-strength melamine tube and nickel-plated end caps for high thermal resistance and corrosion protection in harsh industrial environments.
Common Applications and Practical Usage
The precision inductive protection of the FNQ-R-4/10 TIME DELAY FUSE BUSSMANN makes it essential across industrial automation and electrical control systems:
-
Control Transformer Primary Protection: Ideal for protecting the primary side of low-VA industrial control transformers subjected to high magnetizing startup inrushes.
-
Solenoid & Magnetic Coil Protection: Shields small solenoids, magnetic valves, and actuator coils from sustained overloads while tolerating high initial pull-in currents.
-
Industrial Automation & PLCs: Guards delicate input/output modules, sensing relays, and power supply feed lines inside industrial control panels (ICPs).
-
HVAC & Commercial Controls: Used in commercial HVAC control units, burner ignition systems, and automated damper controls.
Technical Specifications
The core electrical, physical, and compliance parameters for the FNQ-R-4/10 TIME DELAY FUSE BUSSMANN are detailed below:
| Parameter Specification | Technical Details & Operational Values |
| Component Classification | Class CC Time-Delay Current-Limiting Fuse |
| Primary Target Keyword | FNQ-R-4/10 TIME DELAY FUSE BUSSMANN |
| Brand / Series | Eaton Bussmann Series / LIMITRONâ„¢ FNQ-R |
| Amperage Rating | 0.4 Amps (4/10A or 0.40A) |
| Voltage Rating | 600 VAC |
| Interrupt Rating (IR) | 200 kA RMSÂ Symmetrical at 600VAC |
| Response Characteristic | Time-Delay (Min. 12 seconds at 200% current) |
| Fuse Class & Form Factor | UL Class CC Rejection Type (13/32” x 1-1/2” / 10.3mm x 38.1mm) |
| Body Material & Terminals | High-Grade Melamine Tube with Nickel-Plated Bronze Ferrules |
| Agency Certifications | UL Listed (Std 248-4, Guide JDDZ), CSA Certified, CE, RoHS |
Operating Guidelines and Usage Tips
SAFETY NOTICE: Always isolate main power sources and verify de-energized circuits using a calibrated multimeter before inspecting or replacing power fuses.
Transformer Sizing: Size the primary fuse between 125% and 250% of the transformer’s primary full-load amps (FLA) per NEC Article 450 guidelines.
Holder Compatibility: Pair exclusively with UL Class CC rejection fuse blocks or modular DIN-rail holders (such as the Bussmann CHCC series) to utilize the physical safety keying feature.
To review official Class CC time-delay fuse specifications and electrical installation standards, consult the National Electrical Manufacturers Association (NEMA) Directory.
To check regional warehouse inventory availability or request commercial quotes for volume electrical fuses, visit the Control Qatar Contact Page.







