LP-CC-15 LOW PEAK FUSE BUSSMANN
LP-CC-15 LOW PEAK FUSE BUSSMANN – Industrial 15A 600VAC/300VDC Class CC Time-Delay Current-Limiting Fuse
The LP-CC-15 LOW PEAK FUSE BUSSMANN (Model LP-CC-15) is a premium-grade, dual-element time-delay branch circuit fuse manufactured by Eaton’s Bussmann series. Engineered specifically to deliver ultimate overcurrent, short-circuit, and motor-surge protection, this 15-amp, 600 VAC / 300 VDC Low-Peak™ Class CC fuse provides unmatched current-limiting capabilities across industrial control circuits and automated machinery.
Featuring advanced dual-element time-delay technology, the LP-CC-15 LOW PEAK FUSE BUSSMANN holds a minimum 12-second time-delay at 200% of its rated current. This delayed response allows high motor starting currents, transformer magnetizing inrushes, and inductive coil transients to pass without nuisance tripping. Under catastrophic short-circuit conditions, its fast current-limiting operation safely interrupts prospective fault currents up to 200 kA RMS Symmetrical at 600 VAC and 20 kA at 300 VDC. Constructed in a compact 13/32” x 1-1/2” (10.3 x 38.1 mm) body format, it features a physical Class CC rejection tip to prevent non-current-limiting fuses from being inserted into protected circuits
Key Features of the LP-CC-15 LOW PEAK FUSE BUSSMANN
-
Dual-Element Time-Delay Design: Holds a minimum 12-second time-delay at 200% rated load, eliminating nuisance fuse openings caused by motor inrush currents and transformer surges.
-
Class CC Physical Rejection Feature: Built with a standardized rejection tip that mates exclusively with Class CC fuse blocks, preventing accidental over-fusing or substituting lesser-rated devices.
-
High 200 kA Interrupting Capacity: Rated to safely interrupt short-circuit currents up to 200 kA RMS Symmetrical at 600 VAC (20 kA at 300 VDC), ensuring NEC® compliance for high fault-current installations.
-
Extreme Current Limitation: Drastically reduces peak let-through thermal energy (I^2t) and magnetic stress during severe short circuits, safeguarding downstream switches, contactors, and electronics.
-
Dual Voltage Rating: Operates continuously up to 600 VACÂ and 300 VDCÂ (150 VDCÂ per UL marking), enabling application in both AC power lines and DC bus circuits.
-
Compact Physical Footprint: Standardized 13/32” x 1-1/2” size allows high-density mounting inside space-constrained industrial control enclosures and panelboards.
Common Applications and Practical Usage
The high breaking capacity, 15 AÂ rating, and superior surge handling of the LP-CC-15 LOW PEAK FUSE BUSSMANN make it a versatile protection component across automation and power circuits:
-
Small Fractional-Horsepower Motor Circuits: Provides Type 2 “No Damage” short-circuit and overload protection for small AC/DC motor branch circuits.
-
Control Transformer Primary Protection: Protects primary circuits of industrial control transformers against short circuits while withstanding heavy magnetizing inrush surges.
-
Solenoids, Contactors & Relays: Safeguards inductive control loads, electromagnetic valves, and contactor coils from sustained thermal overloads.
-
Industrial Control Panels & Branch Feeds: Essential component for protecting sensitive low-amperage branch circuits and PLC output cards in 600 VÂ machinery panels.
Technical Specifications
The core electrical, physical, and compliance parameters for the LP-CC-15 LOW PEAK FUSE BUSSMANN are detailed below:
| Parameter Specification | Technical Details & Operational Values |
| Component Classification | Class CC Dual-Element Time-Delay Current-Limiting Fuse |
| Primary Target Keyword | LP-CC-15 LOW PEAK FUSE BUSSMANN |
| Brand / Series | Eaton Bussmann Series / Low-Peakâ„¢ LP-CC |
| Catalog Model / Part No. | LP-CC-15 |
| Amperage Rating | 15 Amps (15 A) |
| Voltage Rating | 600 VACÂ / 300 VDCÂ (150 VDCÂ UL) |
| Interrupt Rating (IR) | 200 kA RMSÂ Symmetrical at 600 VACÂ / 20 kAÂ at 300 VDC |
| Response Characteristic | Time-Delay (Min. 12 seconds at 200% current) |
| Fuse Class & Form Factor | UL Class CC Rejection Ferrule (13/32” x 1-1/2” / 10.3 mm x 38.1 mm) |
| Body Material & Caps | Melamine Tube with Nickel-Plated Ferrule Caps & Rejection Tip |
| Agency Certifications | UL Listed (Std 248-4, Class CC, Guide JDDZ), CSA Certified, CE, RoHS |
Operating Guidelines and Usage Tips
SAFETY NOTICE: Always isolate main power supplies and verify circuits are completely de-energized using a calibrated voltage tester prior to inspecting or replacing power fuses.
Holder Compatibility: Install exclusively in dedicated UL Class CC rejection fuse blocks or finger-safe DIN-rail modular holders (such as Bussmann CHCC series holders).
Motor & Transformer Sizing: Follow NEC® Article 430 (Motors) and Article 450 (Transformers) sizing rules when selecting fuse ampacity to balance maximum protection with high inrush tolerance.
To review official Class CC branch-circuit fuse standards and low-voltage current-limiting guidelines, consult the National Electrical Manufacturers Association (NEMA) Directory.
To check regional warehouse inventory availability or request commercial quotes for volume electrical fuses, visit the Control Qatar Contact Page.