LPJ-30SP LOW PEAK FUSE BUSSMANN
LPJ-30SP LOW PEAK FUSE BUSSMANN – Industrial 30A 600VAC/300VDC Class J Dual-Element Time-Delay Fuse
The LPJ-30SP LOW PEAK FUSE BUSSMANN (Model LPJ-30SP) is an industrial-grade, ultimate-protection dual-element time-delay branch circuit fuse manufactured by Eaton’s Bussmann series. Engineered specifically to deliver overcurrent, short-circuit, and motor-surge protection, this 30-amp, 600 VAC / 300 VDC Low-Peak™ Class J fuse combines high interrupting ratings with space-saving current limitation across industrial motor drives and power distribution panels.
Featuring dual-element time-delay performance, the LPJ-30SP LOW PEAK FUSE BUSSMANN holds a minimum 10-second time-delay at 500%Â of its rated current. This allows high motor starting inrush currents, transformer primary surges, and inductive coil transients to pass without nuisance openings. Under short-circuit conditions, its current-limiting capability safely interrupts prospective fault currents up to 300 kA RMSÂ Symmetrical at 600 VACÂ and 100 kAÂ at 300 VDC. Built in a standard UL Class J ferrule body format (13/16” x 2-1/4”), this fuse provides a compact footprint for space-constrained electrical enclosures.
Key Features of the LPJ-30SP LOW PEAK FUSE BUSSMANN
-
Dual-Element Time-Delay Design: Holds a minimum 10-second time-delay at 500% rated load, preventing nuisance tripping caused by heavy motor startup currents and inductive inrushes.
-
High 300 kA Interrupting Capacity: Rated to safely interrupt short-circuit currents up to 300 kA RMS Symmetrical at 600 VAC (100 kA at 300 VDC), ensuring compliance with NEC® requirements for high fault-current systems.
-
Compact UL Class J Form Factor: Standardized 13/16 inch x 2-1/4 inch (20.6 x 57.2 mm) ferrule dimensions save significant space compared to standard Class R or Class H fuses.
-
High-Level Current Limitation: Reduces peak let-through thermal energy (I^2t) and magnetic forces during short circuits, protecting downstream breakers, contactors, and switches.
-
Dual Voltage Operation: Operates continuously up to 600 VACÂ and 300 VDC, serving AC power systems and DC bus power circuits.
-
Type 2 “No Damage” Protection: Helps industrial motor starters and controllers achieve Type 2 protection standards under IEC and UL specifications.
Common Applications and Practical Usage
The high breaking capacity, 30AÂ rating, and surge withstand capability of the LPJ-30SP LOW PEAK FUSE BUSSMANN make it a protection component across heavy industrial applications:
-
Industrial Motor Controllers & VFDs: Protects small-to-medium AC motor branch circuits, soft starters, and variable frequency drive inputs against short circuits and overloads.
-
Control Transformer Primary Protection: Safeguards primary windings of power distribution transformers while withstanding high magnetizing inrush currents.
-
Main & Feeder Branch Disconnects: Serves as primary or secondary overcurrent protection in fused safety disconnect switches, panelboards, and motor control centers (MCCs).
-
Inductive & Resistance Heating Loads: Ideal for process heating equipment, solenoid valves, and commercial HVAC power circuits.
Technical Specifications
The core electrical, physical, and compliance specifications for the LPJ-30SP LOW PEAK FUSE BUSSMANN are detailed below:
| Parameter Specification | Technical Details & Operational Values |
| Component Classification | Class J Dual-Element Time-Delay Current-Limiting Fuse |
| Primary Target Keyword | LPJ-30SP LOW PEAK FUSE BUSSMANN |
| Brand / Series | Eaton Bussmann Series / Low-Peakâ„¢ LPJ |
| Catalog Model / Part No. | LPJ-30SP |
| Amperage Rating | 30 Amps (30A) |
| Voltage Rating | 600 VACÂ / 300 VDC |
| Interrupt Rating (IR) | 300 kA RMSÂ Symmetrical at 600 VACÂ / 100 kAÂ at 300 VDC |
| Response Characteristic | Time-Delay (Min. 10 seconds at 500% current) |
| Fuse Class & Form Factor | UL Class J Ferrule (13/16” x 2-1/4” / 20.6 mm x 57.2 mm) |
| Terminal Connection Type | Ferrule End Caps |
| Body Material | High-Strength Fiber Tube with Metal Caps |
| Agency Certifications | UL Listed (Std 248-8, Class J, Guide JDDZ), CSA Certified, CE, RoHS |
Operating Guidelines and Usage Tips
SAFETY NOTICE: Always isolate main power supplies and verify circuits are fully de-energized using a calibrated voltage tester prior to inspecting or replacing power fuses.
Holder Compatibility: Install in dedicated UL Class J ferrule fuse blocks or finger-safe modular holders (such as Bussmann CH Series Class J holders).
Motor Protection Sizing: Follow NEC® Article 430 rules for motor branch circuit protection, sizing the fuse at 150% to 175% of full-load amps (FLA) to balance overload protection with inrush tolerance.
To review official Class J fuse standards and low-voltage current-limiting overcurrent protection guidelines, consult the National Electrical Manufacturers Association (NEMA) Directory.
To check regional warehouse inventory availability or request commercial quotes for volume electrical fuses, visit the Control Qatar Contact Page.